Product Details:
|
Type: | Temperature Switch | Application: | Electronic |
---|---|---|---|
Size: | Miniature | Voltage Characteristics: | Safe Voltage |
Shape: | SMD Type | Fusing Speed: | FF/Extra Fast |
Implementation Standard: | National Standard | Automatic Reset Function: | Yes |
Maximum Voltage: | 250 (V) | Maximum Current: | 1.5 (A) |
Holding Current: | 1.5 (A) | Operation Temperature: | 0~130 (℃) |
Temperature Control Range: | 0~130 (℃) | Application Area: | Military Industry/aerospace |
Highlight: | KSD01F/JUC-31F 220 Temperature Control Switch,10-95 Degrees Temperature Control Switch,Normally Open Temperature Control Switch |
KSD-01F temperature control switch thermal protector thermostat
KSD-01F is a contact temperature-sensing snap-action plastic-sealed thermostat. It has the advantages of small size, easy installation, sensitive temperature sensing, fast response speed, stable working performance and long service life, less radio interference, safe and reliable. It is composed of highly sensitive bimetallic elements, moving contacts, static contacts, reeds, fixed base plates, wiring pins and other plastic seals.
1 Product Application
This product is widely used in communication power supply, switching power supply, module power supply, audio amplifier equipment, various chargers, rectifier welding equipment, instruments and various high-power electronic and electrical components for overheating protection and temperature control.
2 Appearance and structure:
When working, the bimetallic element is in a free state, the moving contact and the static contact are closed, and the circuit is turned on. When the electrical appliance is heated due to a fault and the temperature rises to the rated action temperature of the product, the bimetallic element generates internal stress due to heat and quickly moves, pushing the moving contact open, disconnecting the contact, cutting off the power supply, and stopping the electrical appliance from working, thereby playing an overheating protection role. When the temperature of the protected electrical appliance drops to the rated reset temperature of the product, the bimetallic element returns to its original state, the moving contact is closed, and the electrical appliance resumes working (the opposite is true for the normally open type).
3. Performance
3.1 Technical parameters
1. Test method:
Install the thermostat on the test fixture and place it in the test area for testing. Use air as the heat conduction medium and place a thermometer or temperature sensor in the temperature measurement area. When the temperature enters the temperature range from the lower limit of the product action and recovery temperature minus 3K to the upper limit of the product action and recovery temperature plus 3K, the temperature rise and fall rate should be no more than 1K/min. During this period, the air in the temperature measurement area must be fully stirred to make the temperature distribution uniform: the temperature uniformity in the temperature measurement area is within 0.4K.
2. Resistance between terminals:
Initial value: ≤50mQ;
After life: ≤500mQ;
Test load: DC 6V, 10mA.
3. Insulation resistance:
Under standard atmospheric conditions, use a DC500V insulation resistance meter to test with a rated voltage greater than or equal to 100mΩ;
4. Electrical strength:
Under standard atmospheric conditions, use an AC voltage of 1800V 50Hz to apply between the lead-out terminal and the ground for 1 minute, without breakdown, arcing, flashover, etc.
5. Ambient operating temperature:
-25℃~+180℃
6. Grounding method:
Connect the outer metal plate of the temperature controller to the grounding metal of the equipment.
3.2
Action temperature and recovery temperature table unit: ℃ (below room temperature) | ||
Action temperature± 5°C | Maximum recovery temperature | Higher than the minimum action temperature |
0 | 20 | 5 |
5 | 25 | 5 |
10 | 30 | 5 |
15 | 35 | 5 |
Action temperature and recovery temperature table unit: ℃ (normal temperature) | ||
Action temperature± 5°C | Maximum recovery temperature | Higher than the minimum action temperature |
20 | 0 | 5 |
25 | 5 | 5 |
30 | 10 | 5 |
35 | 15 | 5 |
40 | 20 | 5 |
45 | 25 | 5 |
50 | 30 | 5 |
55 | 30 | 5 |
60 | 35 | 5 |
65 | 40 | 5 |
70 | 45 | 6 |
75 | 45 | 6 |
80 | 50 | 6 |
85 | 55 | 6 |
90 | 60 | 6 |
95 | 60 | 6 |
100 | 65 | 7 |
105 | 70 | 7 |
110 | 75 | 7 |
…… | …… | …… |
130 | 90 | 9 |
3.3 Dimensions:
Contact Person: Ms. Huang
Tel: 13423305709