Product Details:
|
Rated Current:: | 10A 15A 16A 20A | Breaking Capacity:: | High |
---|---|---|---|
Rated Voltage:: | 250V | Shape:: | Resistor |
Rated Temperature:: | 73℃To 260℃ | Size:: | 62x4mm |
Usage:: | Thermal | Case:: | Metal |
High Light:: | AUPO Thermal Cutoff Fuses, 250V Thermal Cutoff Fuses, 10A 15A 16A 20A AUPO Metal Thermal Fuse | ||
Highlight: | Organic Thermal Cutoff Fuse,Metal Shell Thermal Cutoff Fuse,Thermal Cutoff Fuse 20A |
BF Series BF-I BFX RY AUPO 10A 15A 16A 250V Non Resettable Metal Case Thermal Protector Fuse
Product Description
AUPO BF series product is non-resettable pellet type thermal fuse which prevents electrical appliances from overheating. It has a metal case with pellet material inside and could be used in high current circuits.
BF Series includes: BF, BF-I, BFX, RY.
Advantages
1. Unique pellet formula technology to ensure stable operation and high precision.
2. Complete product quality management system to ensure high consistency and reliability of products.
3. Metal casing design, high sensitivity to temperature rise.
4. Applicable to overheating protection under 10A-16A circuit.
Working Principle
When ambient temperature rises to its operating temperature, the pellet will melt, and the spring a can be released to push the star contact that there is no contact with the pin, thus cutting off the circuit permanently.
Application Field
BF series products are widely used for overheating protection of household appliances, such as small household appliances, refrigerator, washers, kitchen and bathroom appliances; automotive appliances and office equipment,etc.
Product Certification
BF series products meet the safety test requirements of IEC 60691 Ed 4.0 and GB/T 9816.2013, and many models are certified with UL, VDE, CCC, PSE, KC and other safety approvals.
BF AUPO Thermal Fuse
Model No | a | b | c | d | e | f |
BF | 20±1.0 | 11±1.0 | 35±1.0 | Ф1.0±0.1 | Ф4.0±0.1 | Ф1.0±0.1 |
Model NO. | Tf (℃) | Fusing-off Temperature (℃) | Th (℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | Corp | ||||||
BF73 | 73 | 73+0/-10 | 70±2 | 58 | 200 | 10 | 250 |
BF77 | 77 | 77+0/-10 | 74±2 | 62 | 300 | 10 | 250 |
BF84 | 84 | 84+0/-10 | 82±2 | 69 | 300 | 10 | 250 |
BF94 | 94 | 94+0/-10 | 90±2 | 79 | 300 | 10 | 250 |
BF99 | 99 | 99+0/-10 | 95±2 | 84 | 300 | 10 | 250 |
BF104 | 104 | 104+0/-10 | 101+2/-3 | 90 | 210 | 10 | 250 |
BF113 | 113 | 113+0/-10 | 110±2 | 98 | 400 | 10 | 250 |
BF117 | 117 | 117+0/-10 | 114±2 | 102 | 400 | 10 | 250 |
BF121 | 121 | 121+0/-10 | 118±2 | 106 | 400 | 10 | 250 |
BF133 | 133 | 133+0/-10 | 131+2/-3 | 119 | 400 | 10 | 250 |
BF142 | 142 | 142+0/-10 | 138+2/-3 | 127 | 400 | 10 | 250 |
BF157 | 157 | 157+0/-10 | 155±2 | 142 | 400 | 10 | 250 |
BF172 | 172 | 172+0/-10 | 169+2/-3 | 157 | 400 | 10 | 250 |
BF184 | 184 | 184+0/-10 | 181±2 | 169 | 400 | 10 | 250 |
BF192 | 192 | 192+0/-10 | 189±2 | 177 | 400 | 10 | 250 |
BF216 | 216 | 216+0/-10 | 212±2 | 191 | 450 | 10 | 250 |
BF229 | 229 | 229+0/-10 | 226±2 | 201 | 450 | 10 | 250 |
BF240 | 240 | 240+0/-10 | 235±3 | 201 | 450 | 10 | 250 |
BF257 | 257 | 257+0/-10 | 254±2 | 200 | 470 | 10 | 250 |
Model No. | UL/CUL | VDE | CCC | PSE | KTL |
BF73 | E140847 | 40005418 | 2003010205052188 | JET0749-32001-1007 | SU05017-11001 |
BF77 | JET0749-32001-1007 | SU05017-11001 | |||
BF84 | JET0749-32001-1008 | SU05017-11001 | |||
BF94 | JET0749-32001-1008 | SU05017-11001 | |||
BF99 | JET0749-32001-1008 | SU05017-11001 | |||
BF104 | JET0749-32001-1009 | SU05017-11002 | |||
BF113 | JET0749-32001-1009 | SU05017-11002 | |||
BF117 | JET0749-32001-1009 | SU05017-11002 | |||
BF121 | JET0749-32001-1010 | SU05017-11003 | |||
BF133 | JET0749-32001-1010 | SU05017-11003 | |||
BF142 | JET0749-32001-1011 | SU05017-11003 | |||
BF157 | JET0749-32001-1011 | SU05017-11003 | |||
BF172 | JET0749-32001-1012 | SU05017-11004 | |||
BF184 | JET0749-32001-1013 | SU05017-11004 | |||
BF192 | JET0749-32001-1013 | SU05017-11004 | |||
BF216 | JET0749-32001-1014 | SU05017-11005 | |||
BF240 | JET0749-32001-1015 | SU05017-11005 | |||
BF257 | pending | pending | pending | pending |
BF-I AUPO Thermal Fuse
Model No | a | b | c | d | e | f |
BF-I | 20±1.0 | 11±1.0 | 35±1.0 | Ф1.0±0.1 | Ф4.0±0.1 | Ф1.0±0.1 |
Model NO. | Tf(℃) |
Fusing-off Temperature (℃) |
Th (℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | Corp | ||||||
BF73-I | 73 | 63-73 | 70±2 | 58 | 200 | 15 | 125 |
16 | |||||||
BF77-I | 77 | 67-77 | 74±2 | 62 | 300 | 15 | 125 |
16 | |||||||
BF84-I | 84 | 74-84 | 82±2 | 69 | 300 | 15 | 125 |
16 | |||||||
BF94-I | 94 | 84-94 | 90±2 | 79 | 300 | 15 | 125 |
16 | |||||||
BF99-I | 99 | 89-99 | 95±2 | 84 | 300 | 15 | 125 |
16 | |||||||
BF104-I | 104 | 94-104 | 101+2/-3 | 90 | 210 | 15 | 125 |
16 | |||||||
BF113-I | 113 | 103-113 | 110±2 | 98 | 400 | 15 | 125 |
16 | |||||||
BF117-I | 117 | 107-117 | 114±2 | 102 | 400 | 15 | 125 |
16 | |||||||
BF121-I | 121 | 111-121 | 118±2 | 106 | 400 | 15 | 125 |
16 | |||||||
BF133-I | 133 | 123-133 | 131+2/-3 | 119 | 400 | 15 | 125 |
16 | |||||||
BF142-I | 142 | 132-142 | 138+2/-3 | 127 | 400 | 15 | 125 |
16 | |||||||
BF157-I | 157 | 147-157 | 155±2 | 142 | 400 | 15 | 125 |
16 | |||||||
BF172-I | 172 | 162-172 | 169+2/-3 | 157 | 400 | 15 | 125 |
16 | |||||||
BF184-I | 184 | 174-184 | 181±2 | 169 | 400 | 15 | 125 |
16 | |||||||
BF192-I | 192 | 182-192 | 189±2 | 177 | 400 | 15 | 125 |
16 | |||||||
BF216-I | 216 | 206-216 | 212±2 | 191 | 450 | 15 | 125 |
16 | |||||||
BF229-I | 229 | 219-229 | 226±2 | 201 | 450 | 15 | 125 |
16 | |||||||
BF240-I | 240 | 230-240 | 235±3 | 201 | 450 | 15 | 125 |
16 | |||||||
BF257-I | 257 | 247-257 | 254±2 | 200 | 470 | 15 | 125 |
16 |
Model No. | UL/CUL | PSE |
BF73-I | E140847 | JET0749-32001-1007 |
BF77-I | JET0749-32001-1007 | |
BF84-I | JET0749-32001-1008 | |
BF94-I | JET0749-32001-1008 | |
BF99-I | JET0749-32001-1008 | |
BF104-I | JET0749-32001-1009 | |
BF113-I | JET0749-32001-1009 | |
BF117-I | JET0749-32001-1009 | |
BF121-I | JET0749-32001-1010 | |
BF133-I | JET0749-32001-1010 | |
BF142-I | JET0749-32001-1011 | |
BF157-I | JET0749-32001-1011 | |
BF172-I | JET0749-32001-1012 | |
BF184-I | JET0749-32001-1013 | |
BF192-I | JET0749-32001-1013 | |
BF216-I | JET0749-32001-1014 | |
BF229-I | JET0749-32001-1015 | |
BF240-I | JET0749-32001-1015 | |
BF257-I | ○ | |
○ pending |
BFX AUPO Thermal Fuse
Model No | a | b | c | d | e | f |
BFX | 20±1.0 | 11±1.0 | 35±1.0 | Ф1.0±0.1 | Ф4.0±0.1 | Ф1.0±0.1 |
Model NO. | Tf(℃) |
Fusing-off Temperature(℃) |
Th(℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | Corp | ||||||
BF73X | 73 | 73+0/-10 | 70±2 | 58 | 200 | 16 | 250 |
BF77X | 77 | 77+0/-10 | 74±2 | 62 | 300 | 16 | 250 |
BF84X | 84 | 84+0/-10 | 82±2 | 69 | 300 | 16 | 250 |
BF94X | 94 | 94+0/-10 | 90±2 | 79 | 300 | 16 | 250 |
BF99X | 99 | 99+0/-10 | 95±2 | 84 | 300 | 16 | 250 |
BF104X | 104 | 104+0/-10 | 101+2/-3 | 90 | 210 | 16 | 250 |
BF113X | 113 | 113+0/-10 | 110±2 | 98 | 400 | 16 | 250 |
BF117X | 117 | 117+0/-10 | 114±2 | 102 | 400 | 16 | 250 |
BF121X | 121 | 121+0/-10 | 118±2 | 106 | 400 | 16 | 250 |
BF133X | 133 | 133+0/-10 | 131+2/-3 | 119 | 400 | 16 | 250 |
BF142X | 142 | 142+0/-10 | 138+2/-3 | 127 | 400 | 16 | 250 |
BF157X | 157 | 157+0/-10 | 155±2 | 142 | 400 | 16 | 250 |
BF172X | 172 | 172+0/-10 | 169+2/-3 | 157 | 400 | 16 | 250 |
BF184X | 184 | 184+0/-10 | 181±2 | 169 | 400 | 16 | 250 |
BF192X | 192 | 192+0/-10 | 189±2 | 177 | 400 | 16 | 250 |
BF216X | 216 | 216+0/-10 | 212±2 | 191 | 450 | 16 | 250 |
BF229X | 229 | 229+0/-10 | 226±2 | 201 | 450 | 16 | 250 |
BF240X | 240 | 240+0/-10 | 235±3 | 201 | 450 | 16 | 250 |
BF257X | 257 | 257+0/-10 | 254±2 | 200 | 470 | 16 | 250 |
Model No. | UL/CUL | VDE | CCC |
BF73X | E140847 | 40005418 | 2003010205052188 |
BF77X | |||
BF84X | |||
BF94X | |||
BF99X | |||
BF104X | |||
BF113X | |||
BF117X | |||
BF121X | |||
BF133X | |||
BF142X | |||
BF157X | |||
BF172X | |||
BF184X | |||
BF192X | |||
BF216X | |||
BF229X | |||
BF240X | |||
BF257X | ○ | ○ | |
○ pending |
RY AUPO Thermal Fuse
Model No | a | b | c | d | e | f |
RY | 20±1.0 | 11±1.0 | 35±1.0 | Ф1.0±0.1 | Ф4.0±0.1 | Ф1.0±0.1 |
Model NO. | Tf(℃) | Fusing-offTemperature (℃) | Tm(℃) | Tm(℃) | Ir(A) | Ur(V) |
RY73 | 73 | 73+0/-10 | 45 | 150 | 10 | 250 |
RY77 | 77 | 77+0/-10 | 51 | 150 | 10 | 250 |
RY84 | 84 | 84+0/-10 | 58 | 150 | 10 | 250 |
RY94 | 94 | 94+0/-10 | 66 | 150 | 10 | 250 |
RY99 | 99 | 99+0/-10 | 71 | 150 | 10 | 250 |
RY104 | 104 | 104+0/-10 | 79 | 150 | 10 | 250 |
RY113 | 113 | 113+0/-10 | 84 | 150 | 10 | 250 |
RY117 | 117 | 117+0/-10 | 92 | 160 | 10 | 250 |
RY121 | 121 | 121+0/-10 | 94 | 160 | 10 | 250 |
RY133 | 133 | 133+0/-10 | 104 | 160 | 10 | 250 |
RY142 | 142 | 142+0/-10 | 114 | 160 | 10 | 250 |
RY157 | 157 | 157+0/-10 | 127 | 172 | 10 | 250 |
RY172 | 172 | 172+0/-10 | 144 | 189 | 10 | 250 |
RY184 | 184 | 184+0/-10 | 159 | 210 | 10 | 250 |
RY192 | 192 | 192+0/-10 | 170 | 250 | 10 | 250 |
RY216 | 216 | 216+0/-10 | 191 | 280 | 10 | 250 |
RY229 | 229 | 229+0/-10 | 200 | 250 | 10 | 250 |
RY240 | 240 | 240+0/-10 | 200 | 300 | 10 | 250 |
RY257 | 257 | 257+0/-10 | 200 | 450 | 10 | 250 |
Model No. | VDE | CCC |
RY73 | 40005418 | 2003010205052188 |
RY77 | ||
RY84 | ||
RY94 | ||
RY99 | ||
RY104 | ||
RY113 | ||
RY117 | ||
RY121 | ||
RY133 | ||
RY142 | ||
RY157 | ||
RY172 | ||
RY184 | ||
RY192 | ||
RY216 | ||
RY240 | ||
RY257 | ○ | ○ |
○ pending |
The Thermal Cutoff Fuse is a small but essential component in many electrical devices. It is designed to protect against dangerous levels of heat by safely cutting off the electrical current when the temperature reaches a predetermined point. This product is commonly known as a Thermal Shutoff Fusible Link, Thermal Safety Cutoff, Cutoff Thermal Link, or Thermal Cutoff Device.
The Thermal Cutoff Fuse is a small, rectangular-shaped resistor with dimensions of 62x4mm. It is specifically designed for thermal use, making it suitable for a wide range of electrical devices that require temperature control. The fuse is capable of withstanding a range of temperatures from 76℃ to 260℃, making it a versatile and reliable choice for thermal protection.
The Thermal Cutoff Fuse is rated to handle a maximum current of 10A or 16A, depending on the model. This makes it suitable for a variety of electrical applications, from small household appliances to larger industrial equipment.
The Thermal Cutoff Fuse is suitable for use in a wide range of electrical devices, including but not limited to:
Overall, the Thermal Cutoff Fuse is an essential component for ensuring the safety and proper functioning of various electrical devices. Its reliable performance, durable construction, and easy installation make it a top choice for temperature control and protection. Choose the Thermal Cutoff Fuse for peace of mind and efficient thermal protection.
Product Name | Thermal Cutoff Fuse |
---|---|
Rated Voltage | 250V |
Usage | Thermal |
Rated Current | 10A, 16A |
Case | Metal |
Size | 62x4mm |
Breaking Capacity | High |
Rated Temperature | 76℃ to 260℃ |
Shape | Resistor |
Key Features | Temperature Sensitive Circuit Breaker, Thermal Fuse Interlock, Thermal Fuse Thermal Cutoff Fuse |
Brand Name: LinKun
Model Number: RY RYB Series
Place of Origin: China DongGuang
Rated Voltage: 250V
Size: 62x4mm
Case: Metal
Rated Current: 10A 16A
Rated Temperature: 76℃To 260℃
The LinKun RY RYB Series Thermal Cutoff Fuse is a crucial component for ensuring the safety and protection of your electrical appliances. With its innovative design and advanced technology, this thermal shutoff fusible link is designed to prevent overheating and potential fire hazards in home appliances and other electrical devices.
The RY RYB Series Thermal Cutoff Fuse is specifically designed for use in a wide range of electrical appliances, providing essential overheat protection for devices such as hair dryers, toasters, coffee makers, and more. With its compact size of 62x4mm, it can easily fit into the small spaces of your appliances without compromising their performance.
The LinKun Thermal Cutoff Fuse features a sturdy metal case that provides maximum safety and durability. This metal case is designed to withstand high temperatures and protect the internal components of the fuse, ensuring its reliable performance in the event of an overheat situation.
The RY RYB Series Thermal Cutoff Fuse offers a wide range of rated current options, including 10A and 16A, to cater to different electrical appliances' needs. This allows for a more customized and versatile application, ensuring the optimal protection for all your devices.
The LinKun RY RYB Series Thermal Cutoff Fuse is proudly made in China, specifically in DongGuang, with strict quality control measures in place. This guarantees the superior quality and reliability of the product, providing peace of mind for users.
Here are some of the potential applications and scenarios where the LinKun RY RYB Series Thermal Cutoff Fuse can provide essential protection for your electrical appliances:
Whether you are at home, in the workplace, or on the go, the RY RYB Series Thermal Cutoff Fuse is an essential safety component that provides reliable temperature protection for a wide range of electrical devices. Don't compromise on safety – choose LinKun for your thermal safety needs.
Brand Name: LinKun
Model Number: RY RYB Series
Place of Origin: China DongGuang
Rated Current: 10A, 16A
Breaking Capacity: High
Usage: Thermal
Rated Voltage: 250V
Rated Temperature: 76℃ to 260℃
Our Thermal Cutoff Fuse is designed with a temperature sensitive circuit breaker, which is a safety mechanism that automatically shuts off the current when the temperature reaches a certain limit, preventing overheating and potential hazards.
The Thermal Cutoff Fuse contains a fusible link that melts and breaks the circuit when the temperature exceeds the rated limit. This ensures the protection of your electronic devices and appliances from high temperatures.
Our Thermal Cutoff Fuse is equipped with a thermal trip device that activates when the temperature reaches the preset limit, interrupting the current and preventing any potential damage or fire hazards.
The Thermal Cutoff Fuse is carefully packaged and shipped to ensure its safe arrival to the customer. The packaging is designed to protect the fuse from any damage during transportation and handling. The following measures are taken during packaging and shipping:
The Thermal Cutoff Fuse is shipped by a reliable and trusted shipping carrier to ensure timely and safe delivery. The shipping cost will vary depending on the destination and the weight of the package. The customer will be provided with a tracking number for their order, so they can track the status of their shipment.
For international orders, the necessary customs forms will be filled out accurately to ensure a smooth delivery process.
At Thermal Cutoff Fuse, we take great care in packaging and shipping our products to ensure customer satisfaction.
Contact Person: Ms. Huang
Tel: 13423305709