Product Details:
Place of Origin: China DongGuang
Brand Name: LinKun
Certification: RoHS
Model Number: BF Series
Document: Product Brochure PDF
Payment & Shipping Terms:
Minimum Order Quantity: 1000 pieces
Price: Negotiation
Packaging Details: PE bag, Bulk
Delivery Time: 5-7 days
Payment Terms: Western Union, MoneyGram, L/C, T/T
Supply Ability: 100,000 pieces/month

AUPO Metal Shell Organic Thermal Cutoff Fuse 250VAC 10A 15A 20A

Description
Rated Current:: 10A 15A 16A 20A Breaking Capacity:: High
Rated Voltage:: 250V Shape:: Resistor
Rated Temperature:: 73℃To 260℃ Size:: 62x4mm
Usage:: Thermal Case:: Metal
High Light:: AUPO Thermal Cutoff Fuses, 250V Thermal Cutoff Fuses, 10A 15A 16A 20A AUPO Metal Thermal Fuse
Highlight:

Organic Thermal Cutoff Fuse

,

Metal Shell Thermal Cutoff Fuse

,

Thermal Cutoff Fuse 20A

AUPO Thermal Fuse Metal Shell Organic Thermal Fuse 250VAC 10A/15A/20A Thermal Fuse

Product Description:

BF Series BF-I BFX RY AUPO 10A 15A 16A 250V Non Resettable Metal Case Thermal Protector Fuse

 

 

Product Description


AUPO BF series product is non-resettable pellet type thermal fuse which prevents electrical appliances from overheating. It has a metal case with pellet material inside and could be used in high current circuits.

BF Series includes: BF, BF-I, BFX, RY.

 

 


Advantages


1. Unique pellet formula technology to ensure stable operation and high precision.
2. Complete product quality management system to ensure high consistency and reliability of products.
3. Metal casing design, high sensitivity to temperature rise.
4. Applicable to overheating protection under 10A-16A circuit.

 


Working Principle


When ambient temperature rises to its operating temperature, the pellet will melt, and the spring a can be released to push the star contact that there is no contact with the pin, thus cutting off the circuit permanently.

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 1AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 2

 

Application Field

 

BF series products are widely used for overheating protection of household appliances, such as small household appliances, refrigerator, washers, kitchen and bathroom appliances; automotive appliances and office equipment,etc.

 


Product Certification


BF series products meet the safety test requirements of IEC 60691 Ed 4.0 and GB/T 9816.2013, and many models are certified with UL, VDE, CCC, PSE, KC and other safety approvals.

 

 

BF AUPO Thermal Fuse

 

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 3

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 4

 

Model No a b c d e f
BF 20±1.0 11±1.0 35±1.0 Ф1.0±0.1 Ф4.0±0.1 Ф1.0±0.1
Model NO. Tf (℃) Fusing-off Temperature (℃) Th (℃) Tm(℃) Ir(A) Ur(V)
IEC Corp
BF73 73 73+0/-10 70±2 58 200 10 250
BF77 77 77+0/-10 74±2 62 300 10 250
BF84 84 84+0/-10 82±2 69 300 10 250
BF94 94 94+0/-10 90±2 79 300 10 250
BF99 99 99+0/-10 95±2 84 300 10 250
BF104 104 104+0/-10 101+2/-3 90 210 10 250
BF113 113 113+0/-10 110±2 98 400 10 250
BF117 117 117+0/-10 114±2 102 400 10 250
BF121 121 121+0/-10 118±2 106 400 10 250
BF133 133 133+0/-10 131+2/-3 119 400 10 250
BF142 142 142+0/-10 138+2/-3 127 400 10 250
BF157 157 157+0/-10 155±2 142 400 10 250
BF172 172 172+0/-10 169+2/-3 157 400 10 250
BF184 184 184+0/-10 181±2 169 400 10 250
BF192 192 192+0/-10 189±2 177 400 10 250
BF216 216 216+0/-10 212±2 191 450 10 250
BF229 229 229+0/-10 226±2 201 450 10 250
BF240 240 240+0/-10 235±3 201 450 10 250
BF257 257 257+0/-10 254±2 200 470 10 250
Model No. UL/CUL VDE CCC PSE KTL
BF73 E140847 40005418 2003010205052188 JET0749-32001-1007 SU05017-11001
BF77 JET0749-32001-1007 SU05017-11001
BF84 JET0749-32001-1008 SU05017-11001
BF94 JET0749-32001-1008 SU05017-11001
BF99 JET0749-32001-1008 SU05017-11001
BF104 JET0749-32001-1009 SU05017-11002
BF113 JET0749-32001-1009 SU05017-11002
BF117 JET0749-32001-1009 SU05017-11002
BF121 JET0749-32001-1010 SU05017-11003
BF133 JET0749-32001-1010 SU05017-11003
BF142 JET0749-32001-1011 SU05017-11003
BF157 JET0749-32001-1011 SU05017-11003
BF172 JET0749-32001-1012 SU05017-11004
BF184 JET0749-32001-1013 SU05017-11004
BF192 JET0749-32001-1013 SU05017-11004
BF216 JET0749-32001-1014 SU05017-11005
BF240 JET0749-32001-1015 SU05017-11005
BF257 pending pending pending pending

 

BF-I AUPO Thermal Fuse

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 5

 

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 6

 

Model No a b c d e f
BF-I 20±1.0 11±1.0 35±1.0 Ф1.0±0.1 Ф4.0±0.1 Ф1.0±0.1
Model NO. Tf(℃)

Fusing-off

Temperature (℃)

Th (℃) Tm(℃) Ir(A) Ur(V)
IEC Corp
BF73-I 73 63-73 70±2 58 200 15 125
16
BF77-I 77 67-77 74±2 62 300 15 125
16
BF84-I 84 74-84 82±2 69 300 15 125
16
BF94-I 94 84-94 90±2 79 300 15 125
16
BF99-I 99 89-99 95±2 84 300 15 125
16
BF104-I 104 94-104 101+2/-3 90 210 15 125
16
BF113-I 113 103-113 110±2 98 400 15 125
16
BF117-I 117 107-117 114±2 102 400 15 125
16
BF121-I 121 111-121 118±2 106 400 15 125
16
BF133-I 133 123-133 131+2/-3 119 400 15 125
16
BF142-I 142 132-142 138+2/-3 127 400 15 125
16
BF157-I 157 147-157 155±2 142 400 15 125
16
BF172-I 172 162-172 169+2/-3 157 400 15 125
16
BF184-I 184 174-184 181±2 169 400 15 125
16
BF192-I 192 182-192 189±2 177 400 15 125
16
BF216-I 216 206-216 212±2 191 450 15 125
16
BF229-I 229 219-229 226±2 201 450 15 125
16
BF240-I 240 230-240 235±3 201 450 15 125
16
BF257-I 257 247-257 254±2 200 470 15 125
16
Model No. UL/CUL PSE
BF73-I E140847 JET0749-32001-1007
BF77-I JET0749-32001-1007
BF84-I JET0749-32001-1008
BF94-I JET0749-32001-1008
BF99-I JET0749-32001-1008
BF104-I JET0749-32001-1009
BF113-I JET0749-32001-1009
BF117-I JET0749-32001-1009
BF121-I JET0749-32001-1010
BF133-I JET0749-32001-1010
BF142-I JET0749-32001-1011
BF157-I JET0749-32001-1011
BF172-I JET0749-32001-1012
BF184-I JET0749-32001-1013
BF192-I JET0749-32001-1013
BF216-I JET0749-32001-1014
BF229-I JET0749-32001-1015
BF240-I JET0749-32001-1015
BF257-I
    ○ pending

 

BFX AUPO Thermal Fuse

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 7

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 8

 

Model No a b c d e f
BFX 20±1.0 11±1.0 35±1.0 Ф1.0±0.1 Ф4.0±0.1 Ф1.0±0.1
Model NO. Tf(℃)

Fusing-off

Temperature(℃)

Th(℃) Tm(℃) Ir(A) Ur(V)
IEC Corp
BF73X 73 73+0/-10 70±2 58 200 16 250
BF77X 77 77+0/-10 74±2 62 300 16 250
BF84X 84 84+0/-10 82±2 69 300 16 250
BF94X 94 94+0/-10 90±2 79 300 16 250
BF99X 99 99+0/-10 95±2 84 300 16 250
BF104X 104 104+0/-10 101+2/-3 90 210 16 250
BF113X 113 113+0/-10 110±2 98 400 16 250
BF117X 117 117+0/-10 114±2 102 400 16 250
BF121X 121 121+0/-10 118±2 106 400 16 250
BF133X 133 133+0/-10 131+2/-3 119 400 16 250
BF142X 142 142+0/-10 138+2/-3 127 400 16 250
BF157X 157 157+0/-10 155±2 142 400 16 250
BF172X 172 172+0/-10 169+2/-3 157 400 16 250
BF184X 184 184+0/-10 181±2 169 400 16 250
BF192X 192 192+0/-10 189±2 177 400 16 250
BF216X 216 216+0/-10 212±2 191 450 16 250
BF229X 229 229+0/-10 226±2 201 450 16 250
BF240X 240 240+0/-10 235±3 201 450 16 250
BF257X 257 257+0/-10 254±2 200 470 16 250
Model No. UL/CUL VDE CCC
BF73X E140847 40005418 2003010205052188
BF77X
BF84X
BF94X
BF99X
BF104X
BF113X
BF117X
BF121X
BF133X
BF142X
BF157X
BF172X
BF184X
BF192X
BF216X
BF229X
BF240X
BF257X
      ○ pending

 

RY AUPO Thermal Fuse

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 9

AUPO 10A 15A 16A 250V Thermal Cutoff Fuses Non Resettable Metal Case 10

 

Model No a b c d e f
RY 20±1.0 11±1.0 35±1.0 Ф1.0±0.1 Ф4.0±0.1 Ф1.0±0.1
Model NO. Tf(℃) Fusing-offTemperature (℃) Tm(℃) Tm(℃) Ir(A) Ur(V)
RY73 73 73+0/-10 45 150 10 250
RY77 77 77+0/-10 51 150 10 250
RY84 84 84+0/-10 58 150 10 250
RY94 94 94+0/-10 66 150 10 250
RY99 99 99+0/-10 71 150 10 250
RY104 104 104+0/-10 79 150 10 250
RY113 113 113+0/-10 84 150 10 250
RY117 117 117+0/-10 92 160 10 250
RY121 121 121+0/-10 94 160 10 250
RY133 133 133+0/-10 104 160 10 250
RY142 142 142+0/-10 114 160 10 250
RY157 157 157+0/-10 127 172 10 250
RY172 172 172+0/-10 144 189 10 250
RY184 184 184+0/-10 159 210 10 250
RY192 192 192+0/-10 170 250 10 250
RY216 216 216+0/-10 191 280 10 250
RY229 229 229+0/-10 200 250 10 250
RY240 240 240+0/-10 200 300 10 250
RY257 257 257+0/-10 200 450 10 250
Model No. VDE CCC
RY73 40005418 2003010205052188
RY77
RY84
RY94
RY99
RY104
RY113
RY117
RY121
RY133
RY142
RY157
RY172
RY184
RY192
RY216
RY240
RY257
    ○ pending
AUPO Metal Shell Organic Thermal Cutoff Fuse 250VAC 10A 15A 20A 10AUPO Metal Shell Organic Thermal Cutoff Fuse 250VAC 10A 15A 20A 11AUPO Metal Shell Organic Thermal Cutoff Fuse 250VAC 10A 15A 20A 12
Thermal Cutoff Fuse

The Thermal Cutoff Fuse is a small but essential component in many electrical devices. It is designed to protect against dangerous levels of heat by safely cutting off the electrical current when the temperature reaches a predetermined point. This product is commonly known as a Thermal Shutoff Fusible Link, Thermal Safety Cutoff, Cutoff Thermal Link, or Thermal Cutoff Device.

Product Attributes:
  • Shape: Resistor
  • Size: 62x4mm
  • Usage: Thermal
  • Rated Temperature: 76℃ to 260℃
  • Rated Current: 10A, 16A

The Thermal Cutoff Fuse is a small, rectangular-shaped resistor with dimensions of 62x4mm. It is specifically designed for thermal use, making it suitable for a wide range of electrical devices that require temperature control. The fuse is capable of withstanding a range of temperatures from 76℃ to 260℃, making it a versatile and reliable choice for thermal protection.

The Thermal Cutoff Fuse is rated to handle a maximum current of 10A or 16A, depending on the model. This makes it suitable for a variety of electrical applications, from small household appliances to larger industrial equipment.

Key Features:
  • Thermal Protection: The Thermal Cutoff Fuse is designed to protect against dangerous levels of heat by cutting off the electrical current when the temperature reaches a predetermined point.
  • Reliable Performance: With a wide temperature range and rated current, this product ensures reliable and effective thermal protection for various electrical devices.
  • Durable Construction: The Thermal Cutoff Fuse is made with high-quality materials to withstand high temperatures and provide long-lasting performance.
  • Easy Installation: This product is designed for easy installation and can be easily integrated into various electrical systems.
  • Compact Design: The small and compact size of the Thermal Cutoff Fuse makes it suitable for use in a variety of devices, without taking up too much space.
Applications:

The Thermal Cutoff Fuse is suitable for use in a wide range of electrical devices, including but not limited to:

  • Household Appliances (microwaves, toasters, hair dryers, etc.)
  • Electronics (computers, printers, TVs, etc.)
  • Industrial Equipment (ovens, heaters, motors, etc.)
  • Automotive Applications (air conditioning systems, engine control units, etc.)
  • And more!

Overall, the Thermal Cutoff Fuse is an essential component for ensuring the safety and proper functioning of various electrical devices. Its reliable performance, durable construction, and easy installation make it a top choice for temperature control and protection. Choose the Thermal Cutoff Fuse for peace of mind and efficient thermal protection.

 

Features:

  • Product Name: Thermal Cutoff Fuse
  • Size: 62x4mm
  • Breaking Capacity: High
  • Rated Temperature: 76℃To 260℃
  • Usage: Thermal
  • Case: Metal
  • Key Features:
    • Thermal Trip Device
    • Thermal Safety Cutoff
    • Thermal Fuse
    • Thermal Cutoff Fuse
 

Technical Parameters:

Product Name Thermal Cutoff Fuse
Rated Voltage 250V
Usage Thermal
Rated Current 10A, 16A
Case Metal
Size 62x4mm
Breaking Capacity High
Rated Temperature 76℃ to 260℃
Shape Resistor
Key Features Temperature Sensitive Circuit Breaker, Thermal Fuse Interlock, Thermal Fuse Thermal Cutoff Fuse
 

Applications:

Thermal Cutoff Fuse - LinKun RY RYB Series

Brand Name: LinKun

Model Number: RY RYB Series

Place of Origin: China DongGuang

Rated Voltage: 250V

Size: 62x4mm

Case: Metal

Rated Current: 10A 16A

Rated Temperature: 76℃To 260℃


Thermal Safety Cutoff for Temperature Protection

The LinKun RY RYB Series Thermal Cutoff Fuse is a crucial component for ensuring the safety and protection of your electrical appliances. With its innovative design and advanced technology, this thermal shutoff fusible link is designed to prevent overheating and potential fire hazards in home appliances and other electrical devices.

Overheat Protection for Electrical Appliances

The RY RYB Series Thermal Cutoff Fuse is specifically designed for use in a wide range of electrical appliances, providing essential overheat protection for devices such as hair dryers, toasters, coffee makers, and more. With its compact size of 62x4mm, it can easily fit into the small spaces of your appliances without compromising their performance.

Durable Metal Case for Maximum Safety

The LinKun Thermal Cutoff Fuse features a sturdy metal case that provides maximum safety and durability. This metal case is designed to withstand high temperatures and protect the internal components of the fuse, ensuring its reliable performance in the event of an overheat situation.

Wide Range of Rated Current Options

The RY RYB Series Thermal Cutoff Fuse offers a wide range of rated current options, including 10A and 16A, to cater to different electrical appliances' needs. This allows for a more customized and versatile application, ensuring the optimal protection for all your devices.

Made in China with Quality Assurance

The LinKun RY RYB Series Thermal Cutoff Fuse is proudly made in China, specifically in DongGuang, with strict quality control measures in place. This guarantees the superior quality and reliability of the product, providing peace of mind for users.


Applications and Scenarios

Here are some of the potential applications and scenarios where the LinKun RY RYB Series Thermal Cutoff Fuse can provide essential protection for your electrical appliances:

  • Home appliances such as hair dryers, toasters, coffee makers, and more
  • Industrial equipment and machinery
  • Electrical tools and devices
  • Automotive electronics
  • Medical equipment
  • And many more

Whether you are at home, in the workplace, or on the go, the RY RYB Series Thermal Cutoff Fuse is an essential safety component that provides reliable temperature protection for a wide range of electrical devices. Don't compromise on safety – choose LinKun for your thermal safety needs.

 

Customization:

LinKun Thermal Cutoff Fuse Customization Service

Brand Name: LinKun

Model Number: RY RYB Series

Place of Origin: China DongGuang

Rated Current: 10A, 16A

Breaking Capacity: High

Usage: Thermal

Rated Voltage: 250V

Rated Temperature: 76℃ to 260℃

Temperature Sensitive Circuit Breaker

Our Thermal Cutoff Fuse is designed with a temperature sensitive circuit breaker, which is a safety mechanism that automatically shuts off the current when the temperature reaches a certain limit, preventing overheating and potential hazards.

Thermal Shutoff Fusible Link

The Thermal Cutoff Fuse contains a fusible link that melts and breaks the circuit when the temperature exceeds the rated limit. This ensures the protection of your electronic devices and appliances from high temperatures.

Thermal Trip Device

Our Thermal Cutoff Fuse is equipped with a thermal trip device that activates when the temperature reaches the preset limit, interrupting the current and preventing any potential damage or fire hazards.

 

Packing and Shipping:

Packaging and Shipping

The Thermal Cutoff Fuse is carefully packaged and shipped to ensure its safe arrival to the customer. The packaging is designed to protect the fuse from any damage during transportation and handling. The following measures are taken during packaging and shipping:

  • The fuse is first placed in a protective plastic bag to prevent any moisture or dust from entering.
  • The bagged fuse is then placed in a sturdy cardboard box with cushioning material such as bubble wrap or foam to prevent any impact or vibration during transit.
  • The box is sealed with strong packaging tape to ensure the fuse does not shift or move around during shipping.
  • The box is labeled with the product name, model number, and any necessary handling instructions.

The Thermal Cutoff Fuse is shipped by a reliable and trusted shipping carrier to ensure timely and safe delivery. The shipping cost will vary depending on the destination and the weight of the package. The customer will be provided with a tracking number for their order, so they can track the status of their shipment.

For international orders, the necessary customs forms will be filled out accurately to ensure a smooth delivery process.

At Thermal Cutoff Fuse, we take great care in packaging and shipping our products to ensure customer satisfaction.

 

 

 

Contact Details
Dongguan Linkun Electronic Technology Co., Ltd.

Contact Person: Ms. Huang

Tel: 13423305709

Send your inquiry directly to us (0 / 3000)